Vents Uni R A14

Hybrid decentralized universal installation type unit for single-room apartments with an air flow of up to 160 m³/h
  • Sound pressure level LpA at 3 m: 33 dB(A)
  • Sound pressure level LpA at 1 m: 42 dB(A)
  • Heat exchanger type: Plate counterflow
  • Heat exchanger material: Profiled polystyrene plates
  • Supply filter: ePM1 70% / F7 (G4 option)
  • Extract filter: Coarse 90% / G4
  • Sound-insulated casing
  • Bypass: Auto
  • BMS protocol: ModBus
  • Control: Smartphone
  • Casing material: Galvanized steel
  • Humidity sensor: Optional
  • CO2 sensor: Optional
  • PM2.5 sensor: Optional
  • Temperature sensor: Built-in
Unit of measurement Uni R A14
Connected air duct size mm 125
Phases - 1
Minimum supply voltage V 230
Maximum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 58
Unit current A 0.5
Maximum airflow m³/h 60 90 160
Rotation speed at 50hz - 2800
Sound pressure level LpA at 3 m dB(A) 33
Sound pressure level LpA at 1 m dB(A) 42
Heat recovery efficiency, max % 95
Heat exchanger type - Plate counterflow
Heat exchanger material - Profiled polystyrene plates
Weight kg 31
Supply filter - ePM1 70% / F7 (G4 option)
Extract filter - Coarse 90% / G4
Transported air temperature (max) °С 40
Transported air temperature (min) °С -25
Minimum wall thickness mm 70
Maximum wall thickness mm 2000
Vents Uni R A14 44 125 2016
Trademark Vents
Model Uni R A14
Specific energy consumption (SEC) (kWh/(m²/a)) Cold Average Warm
-78.8 A+ -41 A -16.8 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 81
Maximum flow rate (m³/h) 125
Electric power input (W) 52
Reference flow rate (m³/s) 0.027
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m³/h)) 0.271
Control typology Local demand control
Maximum internal leakage rates (%) 2.7
Maximum external leakage rates (%) 2.7
Airflow sensitivity at +20 Pa and -20 Pa (%) 0
Declared typology RVU BVU
Sound power level (dB(A)) 44
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
725 188 143
The annual heating saved (AHS) (kWh/a) Cold Average Warm
8817 4507 2038
Datasheet
"VENTS Uni" product description 02-2023
1.3 Mb
Manual
"VENTS Uni (Max)" user's manual 10-2024 (V231EN-02)
4.02 Mb
BIM/CAD models
Uni
659 Kb
Image
Uni R A14 - image 1
196 Kb
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistat
Vents CO2-3 CO2-3 CO2 sensor
Name Photo Description
Vents NKD 125-0,6-1 A21 V.2 NKD 125-0,6-1 A21 V.2 Inline supply air reheaters with external control
Vents NKD 125-0,8-1 A21 V.2 NKD 125-0,8-1 A21 V.2 Inline supply air reheaters with external control
Vents NKD 125-1,2-1 A21 V.2 NKD 125-1,2-1 A21 V.2 Inline supply air reheaters with external control
Other accessories
Name Photo Description
Vents SF 233x175x22 G4 SF 233x175x22 G4 Panel filter G4
Vents SF 233x175x22 F7 SF 233x175x22 F7 F7 panel filter