Vents Enave-CT 100 P A14 R

Suspended air handling units with a counterflow polystyrene or enthalpy heat exchanger
  • Sound pressure level LpA at 3 m: 32 dB(A)
  • Heat exchanger type: Counter flow
  • Heat exchanger material: Enthalpy
  • Supply filter: G4 / Coarse > 60% (option F7 / ePM1 60%)
  • Extract filter: G4 / Coarse > 60%
  • Sound-insulated casing
  • Enthalpy heat exchanger
  • Control: Wired control panel
  • Casing material: EPP
  • CO2 sensor: Optional
Unit of measurement Enave-CT 100 P A14 R
Connected air duct size mm 100/125
Phases - 1
Maximum supply voltage V 230
Minimum supply voltage V 230
Power supply frequency Hz 50/60
Rated power W 45
Unit current A 0.34
Maximum airflow m³/h 130
Sound pressure level LpA at 3 m dB(A) 32
Heat recovery efficiency, max % 88
Heat exchanger type - Counter flow
Heat exchanger material - Enthalpy
Weight kg 8
Supply filter - G4 / Coarse > 60% (option F7 / ePM1 60%)
Extract filter - G4 / Coarse > 60%
Transported air temperature (max) °С 40
Transported air temperature (min) °С -23
Ambient air temperature min °С 1
Ambient air temperature max °С 40
Ingress protection rating - IP22
Ambient air humidity max % 60
Ingress protection rating of the drive - IP44
Vents Enave-CT 100 P A14 R 45 90 2016
Trademark Vents
Model Enave-CT 100 P A14 R
Specific energy consumption (SEC) (kWh/(m²/a)) Cold Average Warm
-78.6 A+ -41.1 A -16.9 E
Type of ventilation unit Bidirectional
Type of drive installed Variable speed
Type of heat recovery system Recuperative
Thermal efficiency of heat recovery (%) 80
Maximum flow rate (m³/h) 90
Electric power input (W) 37
Reference flow rate (m³/s) 0.018
Reference pressure difference (Pa) 50
Specific power input (SPI) (W/(m³/h)) 0.254
Control typology Local demand control
Maximum internal leakage rates (%) 2.8
Maximum external leakage rates (%) 3
Declared typology RVU BVU
Sound power level (dB(A)) 45
The annual electricity consumption (AEC) (kWh/a) Cold Average Warm
716 179 134
The annual heating saved (AHS) (kWh/a) Cold Average Warm
8776 4486 2029
Datasheet
"VENTS Enave-C 100/120 P" product description 10-2025
1.34 Mb
Manual
"Sensor control panel A14/A15" user’s manual 07-2024 (V55-7EN-02)
1.21 Mb
Manual
"VENTS Enave-C 100 P A14" user’s manual 03-2026 (V224EN-03)
2.95 Mb
Manual
"VENTS Enave-C(T) 100 P A21" user’s manual 12-2025 (V320EN-01)
3.21 Mb
BIM/CAD models
Enave-C 100/120 P - BIM model
999 Kb
BIM/CAD models
Enave CT 100 P - CAD model
961 Kb
Image
Enave-CT 100 P A14 R - image 1
826 Kb
ØD Ød H W L W1
125 104 247 522 530 600
Name Photo Description
Vents HV2 HV2 Humidity sensor
Vents CO2-1 CO2-1 CO2 sensors
Vents CO2-2 CO2-2 CO2 sensors
Vents HR-S HR-S Electro-mechanical humidistat
Name Photo Description
Vents SH-32 SH-32 Hydraulic U-trap to drain condensate from heat exchangers and coolers
Name Photo Description
Vents SR 125/600 SR 125/600 Silencers made of galvanized steel filled with non-combustible sound-absorbing material
Vents SR 125/900 SR 125/900 Silencers made of galvanized steel filled with non-combustible sound-absorbing material
Vents SR 125/1200 SR 125/1200 Silencers made of galvanized steel filled with non-combustible sound-absorbing material
Name Photo Description
Vents KRV 125 KRV 125 Air dampers for automatic air flow control in round ducts
Name Photo Description
Vents Belimo TF230 Belimo TF230 The actuators are designed for controlling air dampers with cross section up to 0.4 m² performing protection functions
Other accessories
Name Photo Description
Vents SF 176x150x22 G4 SF 176x150x22 G4 Panel filter G4
Vents SF 176x150x22 F7 SF 176x150x22 F7 F7 panel filter