| Unit of measurement | Stream 100/125 R | |||
| Speed | - | 1 | 2 | 3 |
| Connected air duct size | mm | 100/125 | ||
| Phases | - | 1 | ||
| Minimum supply voltage | V | 230 | ||
| Maximum supply voltage | V | 230 | ||
| Power supply frequency | Hz | 50/60 | ||
| Rated power | W | 9 | 13 | 21 |
| Unit current | A | 0.81 | 0.09 | 0.1 |
| Maximum airflow | m³/h | 173 | 240 | 320 |
| Rotation speed at 50hz | - | 2252 | 2662 | 2810 |
| Sound pressure level LpA at 3 m | dB(A) | 16 | 21 | 25 |
| Weight | kg | 3.6 | ||
| Transported air temperature (max) | °С | 55 | ||
| Transported air temperature (min) | °С | -25 | ||
| Ambient air temperature min | °С | 1 | ||
| Ambient air temperature max | °С | 40 | ||
| Ingress protection rating | - | IPX4 | ||
| Ingress protection rating of the drive | - | IP44 | ||
| Impeller material | - | Plastic | ||
| Trademark | Vents | |||||
| Model | Stream 100/125 R | |||||
| Specific energy consumption (SEC) (kWh/(m²/a)) | Cold | Average | Warm | |||
| -54 | A+ | -26.9 | B | -11.4 | E | |
| Type of ventilation unit | Unidirectional | |||||
| Type of drive installed | Variable speed | |||||
| Type of heat recovery system | None | |||||
| Maximum flow rate (m³/h) | 320 | |||||
| Electric power input (W) | 34 | |||||
| Reference flow rate (m³/s) | 0.062 | |||||
| Specific power input (SPI) (W/(m³/h)) | 0.106 | |||||
| Control typology | Local demand control | |||||
| Maximum external leakage rates (%) | 2.7 | |||||
| Sound power level (dB(A)) | 28 | |||||
| The annual electricity consumption (AEC) (kWh/a) | Cold | Average | Warm | |||
| 56 | 56 | 56 | ||||
| The annual heating saved (AHS) (kWh/a) | Cold | Average | Warm | |||
| 5536 | 2830 | 1280 | ||||
| Name | Photo | Description |
|---|---|---|
| Vents SR 100/600 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 100/900 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 100/1200 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 125/600 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 125/900 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SR 125/1200 |
|
Silencers made of galvanized steel filled with non-combustible sound-absorbing material |
| Vents SRF 100/600 |
|
Silencers made of aluminium alloy filled with non-combustible sound-absorbing material |
| Vents SRF 100/900 |
|
Silencers made of aluminium alloy filled with non-combustible sound-absorbing material |
| Vents SRP 100/500 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 100/600 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 100/750 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 100/900 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 100/1200 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 100/1500 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 100/2000 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/500 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/600 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/750 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/900 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/1200 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/1500 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Vents SRP 125/2000 |
|
Silencers with an internal flexible air duct made of micro-perforated aluminium foil laminated with polyester film |
| Name | Photo | Description |
|---|---|---|
| Vents FB K2 100 G4/F8 |
|
Panel filters of a high purification level |
| Vents FB K2 100 G4/C/F8 |
|
Panel filters of a high purification level |
| Vents FB K2 100 G4/H13 |
|
Panel filters of a high purification level |
| Vents FB K2 100 G4/C/H13 |
|
Panel filters of a high purification level |
| Vents FB K2 125 G4/F8 |
|
Panel filters of a high purification level |
| Vents FB K2 125 G4/C/F8 |
|
Panel filters of a high purification level |
| Vents FB K2 125 G4/H13 |
|
Panel filters of a high purification level |
| Vents FB K2 125 G4/C/H13 |
|
Panel filters of a high purification level |
| Vents FB K2 100 ES |
|
Panel electrostatic filters of a high purification level |
| Vents FB 100 |
|
Round panel air filters |
| Vents FB 125 |
|
Round panel air filters |
| Vents FBV 100 |
|
Round panel air filters with a large filtration area |
| Vents FBV 125 |
|
Round panel air filters with a large filtration area |
| Vents FBK 100-4 |
|
Round bag air filters |
| Vents FBK 100-5 |
|
Round bag air filters |
| Vents FBK 100-7 |
|
Round bag air filters |
| Vents FBK 125-4 |
|
Round bag air filters |
| Vents FBK 125-5 |
|
Round bag air filters |
| Vents FBK 125-7 |
|
Round bag air filters |
| Name | Photo | Description |
|---|---|---|
| Vents KOM 100 |
|
Backdraught damper with spring-loaded plates for shutting off air flow in round air ducts |
| Vents KOM 125 |
|
Backdraught damper with spring-loaded plates for shutting off air flow in round air ducts |
| Vents KOMu 100 |
|
Backdraught damper with spring-loaded plates for shutting off air flow in round air ducts |
| Vents KOMu 125 |
|
Backdraught damper with spring-loaded plates for shutting off air flow in round air ducts |
| Vents KOM1 100 |
|
Backdraught gravity damper for shutting off air flow in round air ducts |
| Vents KOM1 125 |
|
Backdraught gravity damper for shutting off air flow in round air ducts |
| Vents KR 100 |
|
Air dampers for controlling air flow in round air ducts |
| Vents KR 125 |
|
Air dampers for controlling air flow in round air ducts |
| Vents KRV 100 |
|
Air dampers for automatic air flow control in round ducts |
| Vents KRV 125 |
|
Air dampers for automatic air flow control in round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents VVG 100 |
|
Flexible anti-vibration inserts for round ducts |
| Vents VVG 125 |
|
Flexible anti-vibration inserts for round ducts |
| Name | Photo | Description |
|---|---|---|
| Vents NKV 100-2 |
|
Inline water supply air heaters or heater for air handling units with a round cross-section |
| Vents NKV 100-4 |
|
Inline water supply air heaters or heater for air handling units with a round cross-section |
| Vents NKV 125-2 |
|
Inline water supply air heaters or heater for air handling units with a round cross-section |
| Vents NKV 125-4 |
|
Inline water supply air heaters or heater for air handling units with a round cross-section |
| Name | Photo | Description |
|---|---|---|
| Vents NK 100-0,6-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 100-0,8-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 100-1,2-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 100-1,6-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 100-1,8-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 125-0,6-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 125-0,8-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 125-1,2-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 125-1,6-1 |
|
Round electric inline heaters with round cross-section |
| Vents NK 125-2,4-1 |
|
Round electric inline heaters with round cross-section |
| Name | Photo | Description |
|---|---|---|
| Vents RS-1-400 |
|
Speed controller |
| Vents RS-3,0-T |
|
Applied in ventilation systems for speed switching ON/OFF and speed control of single-phase power-controlled motors |
| Name | Photo | Description |
|---|---|---|
| Vents RS-0,5-PS |
|
Used in ventilation systems for switching on/off and speed control of single-phase fan motors with voltage control |
| Name | Photo | Description |
|---|---|---|
| Vents P3-1-300 |
|
Switch |